Rabu, 22 Februari 2012

Echotouch 3-Wire Ultrasonic Level Transmitter with 24.5' Cable, 2" NPT, 4-20 mA

Echotouch 3-Wire Ultrasonic Level Transmitter with 24.5' Cable, 2" NPT, 4-20 mA

Flowline LU30-5063 Echotouch 3-Wire Ultrasonic Level Transmitter with 24.5' Cable, 50.8mm NPT, 4-20 mA, Sourcing 
The purpose 3-wire ultrasonic transmitter provides the general level of continuous level measurement up to 24.5 "with a 4-20 milliampere output signal, and configured via the display module is an integral push button. Sensor has one level of 10A relay which can be configured on a single set point (high-level alarm or low level alarm) or locked on two set points for automatic fill or empty with a fail-safe logic. This non-contact level sensor suitable for corrosive liquid, ultra pure, sticky or dirty fluids, and is widely chosen for bulk storage and day tank level applications. Range: 6 "to 24.5 ', Accuracy:. + / - 0.25 percent of range Resolution: 0.125 ", the band Death: 6" Beam width: 8 degree cone configuration: push buttons Memory: non-volatile type of display:

Rabu, 25 Januari 2012

Fluke 922 Airflow Meter-Micromanometer Kit

Fluke 922 Airflow Meter-Micromanometer Kit


Fluke Corporations is a world leader in the distribution, manufacture and service of electronic test equipment and software. Since its founding in 1948, happened to have helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to mission critical status in manufacturing and service industries. Of electronic industrial maintenance, installation and service, to precision measurement and quality control, Fluke tools help keep business and industry around the world and running.

The Fluke 922 makes airflow measurements easy by combining pressure, air flow, and velocity in meters, of coarse. The 922 is compatible with most pitot tubes. The Fluke 922 allows technicians to easily enter the channel shape and dimensions for maximum measurement accuracy. Use the Fluke 922 to ensure proper air flow balance and maintain a comfortable environment, measuring pressure drops in filters and coils, and suitable ventilation to occupant loads. The 922 verses in relation to outside pressure monitor, manage the building envelope, and perform traversals of air flow channels for accurate readings.

The 922 provides differential and static pressure, air velocity and flow readings, and the minimum, maximum, average, and hold function for easy data analysis. 922 features a bright, backlit display to see clearly in any environment, and convenient colored hoses help you properly diagnose pressure readings. The power auto off feature saves battery. Fluke 922 airflow meter kit includes: a 12-inch Pitot tube, two rubber hoses, magnetic stripe LFPR, a Strap LFPR, the latch tab LFPR, four 1.5 V AA Alkaline batteries, user manual, all stored in a hard carrying case . Fluke 922 airflow meter kits are sold one set per package and is covered by a warranty of two years.
  • Automatic Frequency Control(AFC)
  • Calculates earth ground impedance at 55 Hz
  • Adjustable limits - for quickertesting
  • 3- pole and 4-pole fall of potential, earth resistance loop testing
  • 4-pole soil resistivity testing
  • Get Fluke 922-Kit Airflow Meter/Micromanometer Kit today!

Rabu, 30 November 2011

Infrared Moisture Analyzer-Infrared Moisture Analyzer-Portable Moisture Analyzers

Infrared Moisture Analyzer-Infrared Moisture Analyzer-Portable Moisture Analyzers


Infrared Moisture Analyzer is a sensitive part of the equipment used to specify the moisture content of various samples. Meanwhile you're sitting on a sample of electronic balance, the room heats the sample with infrared radiation.

MJ33 Infrared Moisture Analyzer
Mettler Toledo MJ33 0.01 Percent Moisture Content Readability Infrared Moisture Analyzer
The MJ33 Infrared Moisture Analyzer offers rugged design, basic functionality, and simple operation for daily routine inspection. It is particularly well – suited for use on the factory floor where samples are tested day in and day out requiring a simple and rugged instrument that provides a very long service life. The MJ33 uses two metal heating elements that dry the sample and deliver reliable results (0.05 percent repeatability moisture content). Routine work is made simple by the instrument led, step by step testing instructions displayed on the LCD back lit display. Fixed end point determination omits the need for programming the switch off criterion further simplifying the operation of the instrument. The MJ33 reliably verifies whether the moisture content meets the specifications, sample by sample, day in, day out.

Halogen Moisture Analyzer
Mettler Toledo HR83P Halogen Moisture Analyzer With Built In Printer
The HR83P Mettler Toledo is the analysis of humidity ideal professional solution for regulated environments. With state of art measurement technology, HR83P allow a reliable analysis of substances with very low the moisture content. A resolution of 0.001 percent and 0.01 percent the moisture content the moisture content measurement repeatability deliver exceptional performance. Circular halogen moisture analyzer 'lamp and gold-plated reflector design ensures excellent reproducibility and rapid heating of your sample. You can also choose from 4 programs drying, a standard step, fast, gentle, and multi for your tailor testing to achieve optimal results within a few minutes. It also comes AutoMet HR83P, methods Mettler Toledo's development program. With AutoMet, the optimal testing methods can be developed for you by the entry of a simple substance of some of the reference and the target value cut development time by 50 percent. Up to 40 test method can be stored for quick and easy to remember and repeat testing. Operation of the moisture analyzer is made easy with backlit LCD and intuitive menus. For full regulatory compliance, HR83P comes equipped with 3 levels of password protection, and fully traceable sample identification and checking of instruments to secure and documented results. HR83P model comes with a built in printer, allowing you to get a print out of your test results without having to connect to an external printer.

Portable Moisture Analyzer

Portable Moisture Analyzer
Convenient and portable, this analysis could see moisture quickly check the performance of gas dryers for compressed air, breathing air and pure gas supplies. Planar capacitive sensor combines accurate dewpoint measurements with fast response time. The sensor is stored in a very dry environment in which speed up the analysis of response time measurements. This instrument can be configured according to the desired moisture unit of measure, unit of measure temperature, or other operating parameters. Measures dewpoint in the shoulder straps come standard planar gas sensors in the drying chamber for various pressure dewpoint measurement fastest response-100C to +20 C humidity user selected measurement unit Fully portable - powered by four common "D" batteries with auto shut down feature two non-IS output large voltage Auto 4 digit LCD screen turn off the timer.

Liquid Level Transmitter-Liquid Level Measurement-Liquid Level Sensor

Liquid Level Transmitter-Liquid Level Measurement-Liquid Level Sensor

Liquid level transmitter LS-10 is designed for economical and reliable performance in a wide range of level measurement applications. LS-10 provides 4-20mA output signal and an accuracy of 0.25 percent of span. Standard pressure ranges are assembled with full-length cable for fast delivery. Compensation for changes in atmospheric pressure is achieved through a ventilation tube in the cable. Many accessories, including cable clamps, dryer drying cartridges, additional weights, and junction boxes are available for special installation requirements. This model can be equipped with attachments LevelGuard for protection in difficult environments. Body: Stainless steel. Pressure connection and diaphragm: Stainless steel. Protective cap: PA. Power supply U (B): 10.


Feature of Liquid level transmitter

WIKA LS-10 Submersible Liquid Level Pressure Transmitter with 40' Polyurethane Cable, 4 - 20mA 2-Wire Signal Output, 25 PSI Range, <= 0.25% Accuracy, G1/2B Pressure Connection

Liquid level measurement in water and wastewater treatment plants, wells, holding tanks, wet wells, rivers. Piezoresistive sensor technology, Ranges from 50 InWC to 400 psi. Rated IP 68 for permanent submersion, Hastelloy case available for aggressive media. 4-20 mA 2-wire output signal, others available, lightning protection available. 145 psi Maximum pressure and 170 psi burst pressure.

Flowline Ultrasonic Level transmitter-Ultrasonic Level Sensor

Ultrasonic Level transmitter-Ultrasonic Level Sensor

Ultrasonic level transmitter detects the level of flow line fluid levels of substance. Liquids and solids of fluid basically flow in the container or tank by gravity whereas most bulk solids pile on the corner of the recess to the top. The substance to be measured can be in a container or can be in natural form (e.g., rivers or lakes). Level measurement values can be either continuous or point. Continuous level transmitter measures level within a certain range and determine the exact amount of the substance in a certain point, while point-level sensors only indicate whether the substance is above or below the sensing point. Generally, the level detected is too high or too low.

Flowline Ultrasonic Level Transmitter for medium tanks

Flowline Ultrasonic Level Transmitter for medium tanks; 2" NPT(M); 12 to 36 VDC; 4 to 20 mA output
Flowline Ricochet Small and Medium Bulk Tank Ultrasonic Level Transmitters and Controllers. Product Type: Ultrasonic Level Controls. Mount: 2" NPT(M). Temp range: -40 to 140°F(-40 to 60°C). Pressure rating: 30 psi at 25°C. Range: 6 in to 12 feet. Beam dimensions: 8° conical width. Resolution: ±0.125". Brand: Flowline. Model: LA20-5001. Power (VDC): 12 to 36. Signal output: 4 to 20 mA. Accuracy: ±0.25% of span. Material: polypropylene housing. PVDF transducerViton® gasket. Part Number: AO-43303-32. Package Quantity: EACH

 Echotouch Flowline Ultrasonic Level Transmitter

Flowline Echotouch Level Ultrasonic Transmitter; power: 18 TO 36 VDC
Order model 43312-00 for general applications. Choose intrinsically-safe, CSA-approved model 43312-10 for use in hazardous locations. Easily install these two-wire transmitters into your process. LCD reads in either inches or centimeters. Order model 43312-00 for general applications. Choose intrinsically-safe, CSA-approved model 43312-10 for use in hazardous locations.

Flowline EchoSpan Ultrasonic Level Transmitter
Flowline EchoSpan Ultrasonic Level Transmitter; 32.8' Range, 2
The general purpose two-wire ultrasonic level transmitter provides non-contact levelmeasurement up to 32 'or 10m, and is ideally suited for challenging corrosive liquids, coating or waste. Transmitters are widely selected for atmospheric bulk sotrage, daytank, process vessel and waste sump applications. Examples include ink and mediawaste water. FEATURES Offered in five measurement ranges up to 32.8 '(10m) with two regular transduser''Luar 7.6 cm diameter beam for applications with limited space the band's amazing 5cm dead optimize the capacity of the small vessels filled Installation is both fast and sim.

Selasa, 29 November 2011

Differential Pressure Transmitters Calibration Guide

Differential Pressure Transmitters Calibration Guide

wire pressure transmitters
Differential pressure transmitter measures the pressure difference between two different environments. Two level transmitters are connected to two columns and used to measure the pressure of a column with respect to other columns. For example, the pressure of a column of water will be reduced from the pressure of other water column to measure the differential pressure. Calibrated pressure transmitter is very important to get the accurate measurement. Pressure transmitter calibration of these devices can be done in a few short steps.
Suunto Wireless Tank Pressure Transmitter for all Suunto Computers
1. The contents of two columns of the pressure transmitter with a liquid. The second column will be connected and will have a level transmitter that is located on the column.
DGC52 : Pressure Transmitter, 0-400" Water

2. Perform the pressure transmitter calibration by setting a single column at the level of 0 percent - that is, even with the level of liquid level transmitters, so the pressure transmitter measures 0 per cent - and one column to be at 100 percent. Selection of level for this column is arbitrary as a transmitter only measure relative changes from one column to another. However, choosing round numbers, such as 1,000 millimeters of water column (mmWC).
CP Pressure Transmitter, 0 To 50 PSIG; 1 To 5 VDC Output, 1/4" NPT(M)


"These OEM pressure transmitter/transducers feature a sputtered thin film sensor to provide consistent high levels of performance and stability for large volume OEMs. A choice of electrical outputs means the unit is suitable for most applications without modification."

3. Multiply the height of the liquid with a specific gravity of liquids and re-calibrate the transmitter to a new height of liquid column to measure pressure in one particular column. Differential pressure transmitter should now be ready to take measurements.

Pda-H315:Trnsmtr -30/0inHg Digital Pressure Transmitter
PDAs Series digital pressure transmitter sensing technology integrates the latest solid state to be very flexible, easy to operate package. Adjustment range of programming features include programmable, pulse ease, zero (between) the adjustment and the user code settable lockout. Ceramic sensing system ensures a very long life cycles with virtually no shift in calibration. These features together with the package, a strong stainless steel compact PDA makes an ideal choice for OEM applications.

High-accuracy pressure transmitters


High-accuracy pressure transmitters with combination ½" NPT(F) conduit/cable compression fittings, 0
Transmitters offer exceptional long-term stability and enhanced accuracy. Typical applications include load weighing systems, compressor and dispensing equipment, lube oil pressure equipment, and factory automated equipment. RFI/EMI and ESD protection circuits exceed CE requirements protecting against noise, voltage spikes and static discharge. State-of-the-art ASIC chip in each transducer provides greater linearity correction than traditional thermal compensation methods.

Senin, 28 November 2011

Tips on Home Blood Pressure Cuffs Calibration

Tips How to Calibrate Home Blood Pressure Cuffs Calibration

Omron HEM-711AC Automatic Blood Pressure Monitor with Standard Cuff
When you are having high blood pressure and your doctor has instructed you to monitor and record your blood pressure at home, you will need to get a home blood pressure monitor cuff. Monitoring your blood pressure at home may be useful for someone who has a "white coat syndrome" and that elevates blood pressure during artificial office.

However be nervous at the doctor, you might ask yourself, how do I know that this house machines accurate? That's a reasonable question because the accuracy of the clinical accuracy of the reading lies with the home machine. So, how does one determine whether home blood pressure machines accurate? Simple. All you need to do is calibrate your home blood pressure cuff. Calibration here means to check the accuracy of measurement of blood pressure in your home with a standard monitor (in this case the doctor). This how to will tell you what you need to do to calibrate monitors and home blood pressure cuff so you'll feel confident in reading 'it.

Here are some tips How to Calibrate Home Blood Pressure Cuffs

Omron Healthcare - New 2007 HEM-711DLX Automatic Blood Pressure Monitor with ComFit Cuff
Purchase of Home Blood Pressure Monitor. They vary in price and size. Some monitors biceps while the other wrist monitors. You might want to check with you are doctor for the type and brand that he recommends.

Schedule an appointment with you are doctor. Tell them you want to calibrate you are home blood pressure monitor.

Take your blood pressure reading at the doctor's office you use your home blood pressure monitor. Write down the reading.
Omron Deluxe Blood Pressure Monitor
Did the doctor or nurse to measure your blood pressure using the office of their blood pressure machine. Write down the reading.

Repeat blood pressure readings in 15 minutes using both machines. This is optional, but it is a good idea.

Compare the two readings. When they are the same - great! If they are off by a few points-note that in your notes. When the difference is quite large, you are may want to return the blood pressure monitor a specific machine and buy a new one.